Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Br J Dermatol ; 188(2): 218-227, 2023 02 10.
Article in English | MEDLINE | ID: covidwho-2316101

ABSTRACT

BACKGROUND: Baricitinib, an oral, selective, reversible Janus kinase (JAK)1/JAK2 inhibitor, is an approved treatment for adults with severe alopecia areata (AA) in the USA, European Union and Japan. OBJECTIVES: To report safety data for baricitinib in patients with severe AA from two clinical trials including long-term extension periods. METHODS: This analysis includes pooled patient-level safety data from two trials, an adaptive phase II/III trial (BRAVE-AA1) and a phase III trial (BRAVE-AA2) (ClinicalTrials.gov, NCT03570749 and NCT03899259). Data are reported in three datasets: (i) the placebo-controlled dataset (up to week 36): baricitinib 2 mg and 4 mg vs. placebo; (ii) the extended dataset (up to the data cutoff): patients remaining on continuous treatment with baricitinib 2 mg or 4 mg from baseline; and (iii) the all-baricitinib dataset (all-BARI, up to the data cutoff): all patients receiving any dose of baricitinib at any time during the trials. Safety outcomes include treatment-emergent adverse events (TEAEs), adverse events of special interest and abnormal laboratory changes. Proportions of patients with events and incidence rates (IR) were calculated. RESULTS: Data were collected for 1303 patients who were given baricitinib, reflecting 1868 patient-years of exposure (median 532 days). The most frequently reported TEAEs during the placebo-controlled period (based on the baricitinib 4-mg group) were upper respiratory tract infection, nasopharyngitis, headache, acne and elevated blood creatine phosphokinase (CPK). During the placebo-controlled period, the frequency of acne was higher with baricitinib than placebo, and elevated CPK was higher with baricitinib 4 mg than placebo and baricitinib 2 mg. In all-BARI, the IR of serious infections was low (n = 16, IR 0.8). There was one opportunistic infection (IR 0.1), and 34 cases of herpes zoster (IR 1.8). There was one positively adjudicated major adverse cardiovascular event (myocardial infarction) (IR 0.1), one pulmonary embolism (IR 0.1), three malignancies other than nonmelanoma skin cancer (IR 0.2) and one gastrointestinal perforation (IR 0.1). No deaths were reported. CONCLUSIONS: This integrated safety analysis in patients with severe AA is consistent with the overall safety profile of baricitinib. Some differences with atopic dermatitis were noted that may be attributable to the disease characteristics of AA.


Subject(s)
Alopecia Areata , Janus Kinase Inhibitors , Humans , Adult , Alopecia Areata/drug therapy , Treatment Outcome , Randomized Controlled Trials as Topic , Janus Kinase Inhibitors/adverse effects , Double-Blind Method
2.
BMC Biomed Eng ; 3(1): 10, 2021 Jun 07.
Article in English | MEDLINE | ID: covidwho-1261282

ABSTRACT

BACKGROUND: In response to supply shortages caused by the COVID-19 pandemic, N95 filtering facepiece respirators (FFRs or "masks"), which are typically single-use devices in healthcare settings, are routinely being used for prolonged periods and in some cases decontaminated under "reuse" and "extended use" policies. However, the reusability of N95 masks is limited by degradation of fit. Possible substitutes, such as KN95 masks meeting Chinese standards, frequently fail fit testing even when new. The purpose of this study was to develop an inexpensive frame for damaged and poorly fitting masks using readily available materials and 3D printing. RESULTS: An iterative design process yielded a mask frame consisting of two 3D printed side pieces, malleable wire links that users press against their face, and cut lengths of elastic material that go around the head to hold the frame and mask in place. Volunteers (n = 45; average BMI = 25.4), underwent qualitative fit testing with and without mask frames wearing one or more of four different brands of FFRs conforming to US N95 or Chinese KN95 standards. Masks passed qualitative fit testing in the absence of a frame at rates varying from 48 to 94 % (depending on mask model). For individuals who underwent testing using respirators with broken or defective straps, 80-100 % (average 85 %) passed fit testing with mask frames. Among individuals who failed fit testing with a KN95, ~ 50 % passed testing by using a frame. CONCLUSIONS: Our study suggests that mask frames can prolong the lifespan of N95 and KN95 masks by serving as a substitute for broken or defective bands without adversely affecting fit. Use of frames made it possible for ~ 73 % of the test population to achieve a good fit based on qualitative and quantitative testing criteria, approaching the 85-90 % success rate observed for intact N95 masks. Frames therefore represent a simple and inexpensive way of expanding access to PPE and extending their useful life. For clinicians and institutions interested in mask frames, designs and specifications are provided without restriction for use or modification. To ensure adequate performance in clinical settings, fit testing with user-specific masks and PanFab frames is required.

3.
Med (N Y) ; 1(1): 139-151.e4, 2020 12 18.
Article in English | MEDLINE | ID: covidwho-988787

ABSTRACT

BACKGROUND: Due to supply chain disruption, the COVID-19 pandemic has caused severe shortages in personal protective equipment for health care professionals. Local fabrication based on 3D printing is one way to address this challenge, particularly in the case of products such as protective face shields. No clear path exists, however, for introducing a locally fabricated product into a clinical setting. METHODS: We describe a research protocol under Institutional Review Board supervision that allowed clinicians to participate in an iterative design process followed by real-world testing in an emergency department. All designs, materials used, testing protocols, and survey results are reported in full to facilitate similar efforts in other clinical settings. FINDINGS: Clinical testing allowed the incident command team at a major academic medical center to introduce the locally fabricated face shield into general use in a rapid but well-controlled manner. Unlike standard hospital face shields, the locally fabricated design was intended to be reusable. We discuss the design and testing process and provide an overview of regulatory considerations associated with fabrication and testing of personal protective equipment, such as face shields. CONCLUSIONS: Our work serves as a case study for robust, local responses to pandemic-related disruption of medical supply chains with implications for health care professionals, hospital administrators, regulatory agencies, and concerned citizens in the COVID-19 and future health care emergencies. FUNDING: : This work was supported by the Harvard MIT Center for Regulatory Sciences, NIH/NCI grants U54-CA225088 and T32-GM007753, and the Harvard Ludwig Center. M.-J.A. is a Friends of McGovern Graduate Fellow.


Subject(s)
COVID-19 , Equipment and Supplies, Hospital/standards , Personal Protective Equipment/standards , COVID-19/epidemiology , COVID-19/prevention & control , Hospitals , Humans , Pandemics/prevention & control , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL